So yes it could be the filter, very clogged and in need of a deep cleaning, but probably not a filter mechanical issue. Holy smokes! Not sure if this is somehow related to the water being heated or maybe air in the pump just guesses. I would start by lubing the pump lid o-ring with pool lube, and trying to tighten the lid a bit more if you can. $579 + Free Shipping in USA. search, pool & drain cover safety Thanks, Jim, if the motor is reversible it will have a Hi Voltage / Lo Voltage diagram printed on the label, and a means to switch it to 115V.
It looks old and Im thinking about replacing it. Look for 4 other bolts, or a clamp band, to pull the motor/impeller out of the wet end, or the pump housing. Holes in grids, or stitching coming apart If the switch does not close after the blower starts the control will go into lockout with the blower running. and check each motor lead to ground. If it still wont catch full prime, open up the pump so you can ream out the impeller vanes with wire or a skinny screwdriver. My Hayward Pump will pull the water through the basket really strong for about 45 seconds then the flow will stop for 20 seconds and the flow will then resume again. So, that leads me to the hose having splits, and drawing air in from a few small slits or holes in the hose, or else the hose is crimping due to the strong suction of the pump. AquaRite not displaying t-xx and getting inspect cell and check salt, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Its a little over 3 years old and the cell checked out fine. "width": "611",
The problem that I have is when I try to start the vacuum to clean the pool. All Rights Reserved. Is it possible that the filter is the problem? Also check that wires are tightly attached, at breaker, timer and pump. When I tighten the impeller onto to the motor how tight should it be? Holding the shaft stationary (so it wont turn), unthread the impeller, counter clockwise, to remove. Its never happened before. Long story short, bought a house that had an above ground pool that would not get the pool clear. I think it only screws on in one direction, but unscrew it to check When in Filter Position, water should route in only one direction. Power is always present at supply input. Then, I tried plugged the pump into another power outlet and it still does not work. Still same though nothing being sucked through basket and minor trickle back out into pool. IF thats good, check the pipe coming into the pump, does it drip when the pump is off? Motor will hum for a few seconds and eventually trip the breaker. If the shaft spins freely, no rust problem. Monday Friday, 8 AM 5 PM. Loud screeching sound from 2 speed 1 HP pump, louder on faster speed. Is the motor set to accept 220V, and matching what you measure at the motor terminals? Breaker for the pump is not tripped. Thanks for your time. If the motor hums, buzzes, or tries to start, but trips the breaker (or not), could be a bound-up shaft, super clogged impeller, bad capacitor, or bad motor. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' Troubleshooting your Hayward salt system Piscines Trvi 8.88K subscribers Subscribe 57K views 3 years ago A salt water system control panel provides all sorts of information. Another possibility could be a clogged pump impeller, should have mentioned that earlier. I dont really know if my pump can be repaired or if the only solution is buying a new pump so soon. I have been getting GFI breaker trips intermittently. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. It is good to let hayward know, because if they had a run of bad bearings, they will know about it, and want to know about it, and are more likely to help, if out of warranty. Regardless, after wiring it up (we did the hot on the bottom and neutral on the top), I put water in the basket and turned on the pump. The pump will draw air in if it can it is easier than pumping water, or the path of least resistance. Troubleshooting Guides To view these documents, you will need to download the free Acrobat Reader, which gives you instant access to PDF files. After reinstalling, give it the full charge of DE powder, plus a little extra. "@type": "Organization",
Unlike the error codes that show up on the digital screen, these problems dont show up as an error notification. if one of the clips or orings is missing, that is another cause of passing DE into the pool. Hi you are getting power inside the motor, on the terminal board? I had my Hayward pool/spa installed about 4 years ago. I have it set for a T9 cell. Usually get 3-4x that long. 1. Check for water under the display, or in the control box area. But higher pressure and no suction, that means an obstruction PAST the impeller. The Inspect Cell LED (only) flashes or stays on when: The Check Salt & Inspect Cell LEDs flash together when: The Check Salt & Inspect Cell LEDs will stay ON when: Step 1: Check your system to confirm that you have programmed the correct cell size. Thanks. It is brand new. I will try that tonight. Hi Vic, pool pump motors have a thermal overload switch that will shut down the motor if temps get too hot. Probably not a pump or motor problem (but could be). You only need to touch both terminals briefly with the tip of an insulated screwdriver, to discharge the capacitor. 220v. Dont feel that resistance when bumping. The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. Hello, my salt generator seems to be always be producing at 100% no matter what my output dial is set at. Shaft seals may blow out if a valve after the pump is turned or briefly closed while the pump is running. Does a Hayward super pump wired on 230v have to have a controller?.. But, If you get no noise at all when you turn on the pump, no humming or grinding, or breaker tripping then check all the power connections, and check for power entering the motor, using a multimeter to test the terminals where the 2 wires connect. When it comes to troubleshooting Hayward pool heater error codes, theres not too much difference between the problem solving process for other gas-fired heaters, made by Jandy, Pentair or Raypak. HAYWARD SALT CHLORINATOR SYSTEM 35K - BLUE ESSENCE-35 This is wholesale site for our registered customers. Does anyone know what Im talking about and/or know how to repair? rialto grand polished porcelain tile 12x24, platypus gravityworks water filter system kit 2-liter, trinity basics ecostorage 5-tier nsf certified rack, Armstrong Human Resource Management 13th Edition Pdf, what is the newest lens for cataract surgery. If you have an automatic controller, it could be a rickety relay or something. Replace with the exact same MFD number capacitor if defective (they can be tested) the capacitor is the battery that starts the motor. The pump has power, turns on, and seals are tight, however it will not cycle the water. please help. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
The new pump is exact same model and when not connected to system it spins and runs fine. A leaking shaft seal should not cause your filter pressure to decrease. No moisture. Baal School; Skill Training for Girls I could take a leap of faith by trying your suggestion of replacing the shaft seal first. So, I dont think you can use this motor, (sorry), unless you are able to add another 110V wire, and run both connected wires from a Double pole breaker. Check the breaker inside the house, make sure its not tripped. Ive checked out your blog and you had very good info for audience. For a better experience, please enable JavaScript in your browser before proceeding. Make sure it is fully pushed into the panel, and the wires are tightly connected, which they likely are. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Why would the pump and Polaris stop working at the same time? Hi Davy, I have a Hayward Super II which has been running well for years. Second most common air leak on a Super Pump would be the incoming pipe fitting. It could also be something loose inside of the tank. Hi, it could be the filter, and if so, the pressure on the gauge would be high during operation usually. We have cleaned it 3-5 times a day and changed the d.e as well. Any ideas? Also, make sure you plug in the cell all the way. Big mistake! After Irma came through, we were without power for a week, the pump wont run on low speed and when it runs at high speed, it overheats after about an hour and shuts off. it continues to cycle this way. Point the capacitor away from you and others, while discharging. Fixing this issue can be tricky, so we suggest you get the help of a certified professional. Shut off the breaker, and timer, and check the tightness of all screws on timer and on pump motor. Write Review Hayward AquaTrol HP Main PCB | GLX-PCB-TROL-HP $375.97 Quantity $17.35 / Month * Platinum Preferred Manufacturer Proposition 65 Warning We purchased a Hayward D.E Filter last summer. v when it is turned to 230v and re wired for 220-230 v it makes no noise at all. We used flocculant and vacuumed through the pump instead of to waste. If you have power coming into the motor, but no pump noise, check (Power off) that wire connections are tight, and inspect the wire for breaks or damage. 58 amps! I have the intermatic digital two speed timer. When we turn on power, the pump does not make noise but the timer box and the circuit box make a light humming noise and then the circuit tripped. The stationary switch copper tabs may be bent, or may have a wire crossing between them, have a loose screw or have some other issue that prevents it from opening, and releasing the capacitor. Hi Martha, open the air bleeder, perhaps there is a lot of air in the tank, drawn in by the pump. Hi Tim, If Assy A has a bad motor (test it? The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. Read up on it and seems it happens a lot and the motor drive needs to be replaced. You can also turn off the pump at the breaker which provides power to the timer. Frayed wiring inside the plug or socket. I just purchased a new pump and installed it but once all the hoses are connected even with the pump off the pump is leaking from the strainer housing. Also check other wires in the back of the motor. My pump, when in the normal running position, leaks water in a slow steady flow out the tubing used for backwashing. Anyone have similar problems or have an idea what we r doing wrong? Is it time for a replacement pump? Its less than 2 wks old. It did never tripped during program. Valves were replaced with pipe and silicone applied to gaskets and O-rings during install and again yesterday while I was checking this list. put in a new motor and had the old motor repaired. . It can continue to run at that point but its almost like its running at 25% power or even less so we just turned it off. You can consult the flow charts for each model, to compare flow rates among two pumps, with a given (or assumed) level of resistance (feet of head). Hi if a 2-speed motor only works on low speed, that is usually a loose wire or hi/lo switch. Hi Michael, common problem, which can be caused by a variety of issues, in order of possibility I was hoping that you can give me some advice. Step 3: Double check the wires on the flow switch for damage. dr myers ultrasound. If assumed to be the capacitor, get the MFD number printed on it, and find an exact replacement capacitor on our site, or from a local electric motor shop. This noise does not happen when the water is flowing through the heater but it is not turned on. Any idea what could be causing this issue. Good thing is our power company is offer rebates for new energy efficient pumps. Try to spin the impeller by hand, to be sure that the motor shaft spins freely and is not bound-up. The post-purge cycle will be completed once the blower prover switch closes. The o-ring should be a very tight fit also, not loose in the groove of the lid. Any new postings here are unlikely to be seen or responded to by other members. Question my Aquaririte is 3 years old. What is the incoming voltage on a H-150 pool/spa heater ? I never had this problem before. Is it a defective motor or something else? Diagrams, Pool Is there a reset button or do I just need to wait until the water evaporates and it should turn back on? Or maybe the glue that Im assuming is no longer working? Just started getting a No Flow error. When turned on, it clicks in and off every few seconds. This worked well until about 4 years ago, when I replaced it with a similar pump, a Hayward sp2607x10. You must log in or register to reply here. Use Teflon pool lube on the pump lid o-ring, reapply every 4 months. They disparate as they move through the pool. If that doesnt solve the problem, then work through the steps below. The pump works and will pump out whatever water is in the line, but wont prime and suck the water from the pool. If you have other questions, you can email me Davy, at swimmers@intheswim.com. Hi Jack, according to the manual, the Drive Error Pump is Stalled error usually refers to water or moisture on the circuit board, under the display panel. the pump is working but not priming. I just had a power surge in my area and the heater has been turning on and wont turn off. Go to the grocery store and come back and its dead. If you havent inspected your cell yet, now is aperfect time. Mine hums and then trips the breaker. I have no display showing. Typically, any dilemmas with your Hayward pool pump are likely related to either electrical or plumbing situations. With a flashlight (and your glasses), you can also look into the Visual Motor Check hole in the top of the mechanism, you should see gears moving. I flipped on the breaker and the pump made this god awfully loud noise, immediately flipped it off. There are some pumps that will draw air in thru a faulty shaft seal, which will leak water, dripping below the pump, when the pump shuts off. Your old motor may have been uprated, and new one full rated? Remove the filter cartridge to see if it continues. I have an older Haywood super pump 3/4 hp, i replaced it with a new 3/4 hp motor. Thank you I have a Hayward super pump 1HP. Or, it could be that the motor is cavitating, and restricting the return side somewhat may balance the flow, if you have a valve or bypass arrangement, or can plug one of the returns, for testing. Thanks for your insight. If the spa is draining while in spa mode, it must be sending some water back to the pool, either the valve is not closing all the way, allowing some water to return to the pool. Never had an issue with the other motors we have had. the tubes are sealed at the end by the two seal plates. To spin the shaft, to find out of it spins freely, open up the rear of the pump motor, with power off, and use your fingers to spin the shaft. Usually its 4 bolts or its a clamp band that connects the seal plate to the volute or strainer housing. We dont have mechanical time clocksit is all digital. Inspect for any damage to wires or wire casing. Got a new motor, it made humming noise since day on,if i help it spin it works so I changed the capacitor and still the same, humming and if I help it to spin it goes fine, any suggestions? Turn on heater and see if you can narrow down the noise. After cleaning the pool the pool pump would just hum and not start. I owe you a beer if you are ever around my neck of the woods. Could need cleaning. "dateModified": "05/20/2022",
Just opened up the pool and the Hayward Super Pump worked just fine until we started vacuuming the bottom. Just a thought Do you have it set at super chlorinate ? Its a good piece of troubleshooting. Check fan and shroud for blockage. You may need to start shopping for a new motor and shaft seal, or a whole new pump of the same size and type. registration, authorized Hi Be sure the wiring is tight on both ends. Any new postings here are unlikely to be seen or responded to by other members. this is the black cylinder in the rear, at 9 oclock. I just replaced the seal and all of the gaskets along with carefully cleaning the grooves that the gaskets rest in and greasing them thoroughly with Jacks. Motors have a thermal overload switch (in the rear of the motor, top-dead-center, at 12:00). 908-355-7995. pull the water through. Hi Rodney, well the Green wire should be ground, so that eliminates one choice. Also they winterized the place where the water circulates inside the pool and it wont unscrew so we can let some of the water out and put the original piece back on. "@type": "ImageObject",
Poor connection inside the plug or socket. Yes, if not grounded correctly, the GFCI will trip. I checked the pump and is is very hot. The process, for changing a hayward pump seal is: 1. with UV, Ozone and Hydroxyl Radicals. Incorrect sizing can cause multiple problems, including low water flow. Usually however, a howling or moaning sound from the pool heater, is low water flow. I went out Toto shut it off so I could backwash and add chlorine. You can, if possible, vacuum to waste by setting the multiport on the Drain to Waste setting, and then vacuuming fast you will discharge silty debris out of the pool. If the backwash line continues to leak, remove the multiport valve lid and inspect the spider gasket for wear or damage in the waste port area. how to watch past broadcasts on twitch. Some very old pumps have impellers that need shimming from time to time, or resetting the distance from the volute, but thats with keyed shaft motors, on older bronze pumps (not plastic). I set up to measure motor current, using 100amp, 100mv shunt, the current draw is 6.5 amps @241V (Pump pressure about 17-18 psi) The wire size may depend on the distance of wire run. What could I be missing that would cause this? Also check the threaded pipe that comes into the pump, #1 most common air leak. The hub was leaking and had to be replaced. We have all these parts here: https://www.intheswim.com/c/valve-parts, I Installed a new Hayward VCSB216V solar pump. Could also be a loose high speed wire from the switch. 6. Your chlorine generator is still producing chlorine at the moment, which is a good thing. Could be the pump lid, drain plug, or the pipe that threads into the pump. Help. I will be purchasing a replacement pump and have it installed, but I wonder if Id need to just have the breakers tightened in the panel box? When you installed the new lateral assy, did the standpipe come all the way up to the top of the tank, and insert neatly into the bottom of the multiport valve? The pump top is under suction, not pressure (like the filter). My pump motor does not start until I spin the shaft then it runs for about 15 min and shuts off and I can hear the motor humming and it feels very hot to the touch. If the pump is too large and powerful for the system and pipe size (and Northstars are BIG pumps), the cavitation can cause the motor to overwork. Now I am looking to replace the old filter. It ran all night and still going. A leaking shaft seal or drain plug could also drain the pump after some time. The electrician also installed w new capacitors on the pump and still same problem. When running through all these checks and balances if it is noticed that there is not bond wire or that the tightening screws are not all secure, correct the issue. K-1766 Taylor Salt Test I have a Hayward pro series filter and Hayward pump. On an Intermatic timer clock, there is a tab, at around 4 oclock on the dial, that is pushed to the left to turn off the timer, or override the timer settings. $8.99 $5.99 As low as $4.49 Dow Corning - Molykote 111 6 gram O-ring Silicone Lubricant and Sealant - Be sure to lube your O-rings to help prevent leaks. I turned it on and it ran fine for about one hour. Looking for pool parts? men's rhinestone dress shoes. I have an older Hayward Pool pump for an above ground pool. I wonder if I should spend the $200 for replacement control board, or if there is a better fix. Now what? Everything is Primed and ready to go, soon as I put the vacuumin on the skimmer, the pressure stays for about 30 secs then the pressure and water level drop to next to nothing. Now it wont flip back on but it is still raining hard. If the bolts do not tighten fully, it could be that the housing threaded receivers are loose and spinning as you try to tighten the bolts. All check ok. If it makes no noise at all, that is often a loose wire or no power. BUT THE BEARINGS. It could also be that the power cord is not rated for 15 amps, which is the likely size of the breaker for the outlet (but check the breaker amp size). Hi John, the cap for that motor is START CAPACITOR, 161-193 MFD (BC-161) we dont carry it, but easily found online. The repair for such an issue is to remove the 6 screws around the lid (dont lose the nuts), and pull the handle to lift the key assembly out of the valve body, where you can inspect the gasket, in the area of the backwash port. For Use With: Hayward AquaTrol Pool Chlorine Generator Brand: HAYWARD REVIEWS Q&A Powered by TurnTo Review More Purchases | My Posts There are no reviews for this item. Drain plugs, pump lid, pipe coming into pump, skimmer or main drain valves, low water level, stuck skimmer weir, or the dreaded underground cracks in pipe (rare problem). I get home from work and the pump is running. Step 2: Verify the accuracy of the salt readings (2700-3400 pm) with an independent test kit or by taking a water sample to your local pool store for testing. If stuck from rust build-up, move the capacitor (located at 9 oclock) and/or the thermal regulator (located at 12 oclock), out of the way, so that you can fit a 7/16 open end wrench on the slotted part of the shaft, behind the centrifugal switch that is screwed onto the end of the shaft. Wouldnt, the other three still be sufficient to filter? I checked the voltage at the back of the motor and have 240 volts. The volute screws (around the impeller housing) do not need to be removed. If it sounds loud and grumbly, that can be a sign of cavitation, being starved for water, from not enough water being supplied (it wants more). partially collapsed, or partially clogged skimmer line. Your thoughts? I am very sure the water comes from underneath, not from plumbing fitting threads. They function as the starting battery for the motor, to help it get up to speed quickly. Be sure though, that the motor has plenty of air flow, and the air flow vents are not blocked, and that incoming voltage is not too high or too low. Is it problem of filter ? I have a Heyward VS 500 that suddenly started making a sound like a poker card stuck in your spokes of your bike at all speeds. Step 4: If none of the previous steps solved the problem, replace your flow switch. Now there is no water running from the pool to the motor basket. Vacuum hose air leaks from splits in an old hose. Hayward recommends 1.5 PVC pipe, and more than one line, (i.e. 1.5 horse power. So, if you replaced the handle assembly and valve, aka the Key Assy, item SPX0714BA, and water is still coming out of the backwash line? Or a stuck skimmer weir. It should be the receiving 115V or 230V, depending on how it is wired, plus/minus 10%. Essentially, its probably something loose/broken, or a bad capacitor, which is like the battery to help it get up to high speed. 6. They are cheap and easy to replace. "caption": "In The Swim Blog"
BLUE WORKS PCB Main Circuit Board Compatible with Hayward Goldline GLX-PCB-Main System Board Visit the BLUE WORKS Store 193 ratings $16999 FREE Returns Available at a lower price from other sellers that may not offer free Prime shipping. hI, the impeller ring should go small side toward the impeller, they are often marked as such. Any ideas as to what could be the problem? Could be a short in the wiring that could be tested with an Ohm meter, for resistance. Just bought a brand-new Hayward pump , starts up in primes great but in about five minutes there was no suction or water flow back to the pool . Cracked Seal on Case Completely Dry inside. Hi Mike, when there is no wiring diagram printed on the motor label or above the nameplate, indicating High/Low Voltage wiring specs, then the motor is not reversible. The most common places for an air leak on a pump include around the pump lid (must be really tight, with lubed o-ring), or a loose incoming water pipe bringing water (and air) into the pump. A sticky skimmer weir door can cause water blockage to the skimmer, and give priming problems too. If it is cycling on/off (motor turning on/off) more rapidly, that would usually indicate loose wires, loose breaker, broken wires (sometimes inside the flexible conduit). It ran and then we shut it off. Although in low speed, chlorine is not generated so not sure why even run the low speed. Inground pool, 1 Bought new vac hose now own 3 Appreciate any help. Thanks, When the centrifugal switch is pushed flat by the spinning shaft (or with your finger [power off! However, I havent tried to spin the shaft. Also, DE filters need to be opened up and hosed down completely clean every 6-9 months, and then started up again with a full charge of DE powder. When I flip a switch to manually turn on to high speed, it does not work it is still working at low speed. Third, is there a valve closed after the filter, or some other obstruction? The new pump runs great and only once every day or so do we notice that the pump is off and that the breaker is tripped. On initial trial for ignition. I took apart the impeller and didnt see anything that could cause a problem. On a DE filter, water enters the tank through the bottom tank bulkhead, and is when the tank fills up, water is forced through the grids, and then up thru the manifold, and down the standpipe to the top exit bulkhead DE inside the grids, must have been missing an o-ring before, a push-pull valve plunger ring? Plunger was a good idea, a Drain King can also be used, from the pump, to blow debris back to the skimmer. If the impeller spins freely, does that mean the shaft is spinning freely or do I need to try to turn it from the back of the motor? Check for possible disruption inside of the flow T. Installation requires 12 inches of straight pipe before the flow switch. of and to in a is " for on that ) ( with was as it by be : 's are at this from you or i an he have ' not - which his will has but we they all their were can ; one also the Following this procedure will identify Royal Tulip Beach Resort is located near Port Ghalib, 42 km from Marsa Alam. ), it could be a bad breaker, they can fail or become too sensitive with age. Call Hayward and speak to their tech support people, for more precise advice. New Assy is $500. Anyway I decided to run it and it appears that the pump runs full power with the returns pushing out with lots of force for about 5 minutes and then it weakens. And since it was running before (it shut off), its probably not rust. Hayward Blue Essence Troubleshooting, Pool Supplies Near Me Open Now, Breville Tamper Coffee Kit 54mm, Used Cozzia Massage Chair, Power Pole Distribution Block, Signature Custom Cabinetry, hayward blue essence troubleshootinghi-c orange lavaburst bottle hayward blue essence troubleshooting Destacado beach outfit ideas for chubby